There are many kinds of emergency lights. Among them, portable emergency lights, fire emergency lights, energy-saving emergency lights, and supply emergency lights are widely used and high-quality products Shenyang emergency fire lighting What are the advantages of being an emergency light? How to install and maintain.
Fire emergency light is applicable to fire emergency lighting and is a commonly used lighting tool in fire emergency. It has the functions of long emergency time, high brightness and automatic emergency in case of power failure. The fire emergency lamp has the characteristics of low power consumption, high brightness and long service life. There are power switches and indicator lights on the side, which are suitable for emergency lighting in public places such as factories, hotels, schools and units when power is cut off.
The fire emergency lamp is made of industrial plastic and high brightness bulb. The color is mainly white. The surface has two arrows. The material is not aging, with fast heat dissipation and impact resistance. Fire emergency lights are wall mounted, portable and suspended.
Code for installation of fire emergency lights
1. In the engineering design, in order to facilitate the maintenance and management at ordinary times, the fire emergency lighting uses a dedicated feeder circuit on each floor for power supply.
2. In order to ensure the reliability of the fire emergency lighting power supply, the low-voltage emergency bus section of the substation shall be used for power supply as far as possible, that is, the diesel generator set shall be used as the emergency supply As long as the generator is put into use, there will be power to continue to ensure power supply.
3. In case of fire, there is less smoke and more oxygen near the ground. The instinctive reaction of people to evacuate is to bend down or climb forward. Therefore, local high illuminance lighting is more effective than the uniform illuminance brought by high level installation. Therefore, low-level installation should be advocated, that is, evacuation emergency lighting should be set near the ground or on the ground.
4. The emergency light is discharged when it leaves the factory, and it can only be discharged after 20 hours of charging.
5. The emergency lamp in use shall be checked regularly. Every half month or one month, it shall pass the continuous switch test to check the circuit conversion and battery emergency function, and discharge to extend the battery life.
6. Do a good job in fire prevention of distribution lines. When laying in the dark, it shall be laid in the incombustible structure, and the thickness of the protective layer shall not be less than 30mm; When laying in the open air, the steel pipe shall be threaded through the metal pipe, and the steel pipe shall be coated with fireproof coating or other fireproof measures shall be taken; Use fire-resistant cables or fire-resistant cables and wires.